Homogenization, dispersion, cell disruption, degassing, disaggregation, deagglomeration, mixing, emulsification, catalysis of liquid samples

NexTgen Technology main features: NexTgen ultrasonic power generator

 TECHNICAL INFORMATION  NexTgen LAB120  NexTgen LAB500  NexTgen LAB750
 CONTINUOUS max. RMS POWER  120 Watt  500 Watt  750 Watt
 FREQUENCY (kHz)  35  20  20
 CONTINUOUS MODE  yes  yes  yes
 PULSE MODE  yes  yes  yes
 VOLTAGE (V)  110-240  220-240  220-240
 OTHER VOLTAGE  -  on request  on request
 DIMENSIONS (LxWxH)  330x145x148mm  390x145x148mm  390x145x148mm
 WEIGHT  3,5kg  4,3kg  4,5kg
 REMOTE START/STOP  Pushbutton/Footswitch  Pushbutton/Footswitch  Pushbutton/Footswitch
 TOUCH SCREEN INTERFACE  LabTablet  LabTablet  LabTablet
 COMMUNICATION AND CONTROL  Ethernet  Ethernet  Ethernet
 PC-SOFT NexTgen “Advanced”  optional  optional  optional
 TEMPERATURE SENSOR  optional  optional  optional
 MONITORING      
 Microprocessor based  Digital signal Processor    
 Automatic tuning  Yes (start frequency and max-min frequency are adjustable with "advanced software")    
 Phase control  Real time phase/ frequency control    
 Automatic amplitude compensation  Real time output amplitude control    
 COMMAND /SETTING PARAMETER      Managed by our PC-software "Advanced"
 Frequency  Set the auto-tune range  Set the auto-tune range  Set the auto-tune range
 Power/Amplitude  10% to 100% max power  10% to 100% max power  10% to 100% max power
 Timer  from 0,5s to 10h  from 0,5s to 10h  from 0,5s to 10h
 Pulse/cycle repetition  from 1 to 10,000  from 1 to 10,000  from 1 to 10,000
 Multiple program sequencer  up to 10 programs  up to 10 programs  up to 10 programs
 Start/Stop  Footswitch/Pushbutton    
 Stop conditions  Pushbutton/footswitch/software/ time/energy/temperature (with temperature sensor) setting    
 Start conditions  Pushbutton/footswitch/software/temperature (with temperature sensor)/setting    
 DATA TREATMENT  Managed by our PC-software "Advanced" (optional)    
 On demand real-time Display  3 real-time curves during the process:    
 Post treatment data:  Exportation to EXCEL for statistical post analysis:    
 Frequency measurement  Parameters :  Frequency/Phase  
 Wattmeter/amplitude    RMS Power/amplitude on transducer  
 Energy measurement    Energy with possible adjustments of energy level  
 Temperature measurement    Temperature from external sensor (option)  
 Elapsed time indicator    Yes  
       
       

 Model  Probe Type  Diameter  Processing Volume  Amplitude
 LAB 120  Micro Tip /solid Titanium  Ø 3 mm  0.2 ml  - 50 ml  140 µm
 Lab 120    Ø 6 mm  2 ml  - 50 ml  140 µm
 Lab 500  Standard /solid Titanium  Ø 13 mm  20 – 500 ml  140 µm
 LAB 750    Ø 20 mm  100 – 1000 ml  60 µm
     Ø 25 mm  200ml - 1500 ml  35 µm
 LAB 750R    Ø 30 mm  400 – 2000 ml  RADIAL

*The indication of minimum and maximal volumes is purely indicative. A large number of parameters, such as the nature of the sample, its viscosity, the size and shape of the test tube…… have a significant impact on the volume range.

Sonicator (Radial Type)



Homogenization, degassing, disaggregation, mixing, deagglomeration, emulsification, catalysis of liquid samples