| Diamond – Fully Automatic Immuno-Analyzer takes care of sample and reagent handling to well washing and optical measurement with a touch of a button. Diamond is a convenient and accurate fully automated system specialized for CLIA (chemiluminescence immunoassay) and ELISA (enzyme-linked immunosorbent assay) - Fully automated immunoassay system (luminescence, absorbance measurement) - Open platform - Compatible with conventional 96-well plates - Quick and accurate control - Minimized inter-well cross contamination through the use of disposable tips - Accurate liquid handling |
| General | |
| Sample Capacity | 96 Patient Sample Positions |
| Reagent Capacity | 9 Custom Reagent Positions |
| Test Tube | Standard 13, 16 mm diameter (Customizable) |
| No. of Microplate | 2 |
| Well-tracking | Independent well tracking & timing |
| Barcode Reader | Optional |
| System Architecture | Universal Open Platform (Qualitative and Quantitative) |
| Sample Tray | Easy loading and unloading of samples |
| Dimension | 650 x 830 x 650 mm |
| Power | 100 – 240 V, 50 – 60 Hz |
| ELISA Reader Specification | |
| Dynamic Range | 0 – 3.0 OD |
| Photometer | 450, 630 nm (Optional: 405, 490, 550 nm) |
| Filter Slots | 6 |
| Precision | <1% CV (2.0 OD) |
| Accuracy | ±0.005 OD or 2.5% |
| CLIA Reader Specification | |
| Dynamic Range | Up to 7-log of dynamic range |
| Limit of Detection | 1 x 10-18 moles of ATP |
| Crosstalk | 3.0 x 10-5 |
| Washer | |
| Manifold Configuration | 8 Channels |
| Dispense-volume Range | 100 – 300 µl |
| Washing Tank | 2 External Washing Tanks and 2 Waste Tanks |
| Wash Cycle | 1 - ∞ (Customizable) |
| Residual Volume | <1 µl |
| Incubator | |
| Temperature Range | Up to 42℃ |
| Temperature Uniformity | ±0.5℃ |
| Shaking | Amplitude: 1 mm, Speed: Up to 800 RPM |
| Temperature Monitoring | Yes |
| Pipetting | |
| Aspiration Volume | >5 µl |
| Tip | Disposable |
| Serial Dilution | Yes |
| Replicates | Yes |
| Precision | <0.8% CV at 100 µl |
| Process Security | |
| Liquid-level Detection | Yes (Optional) (Must use disposable tips from MicroDigital) |
| Level-sensor System | Pressure Differential |
| Dispense-anomaly Detection | Yes (Optional) |
| Tip Detection | Yes (Optional) |
| Well-fill Verification | Yes |
| Alarms | Warning Message on PC Software |
| Software | |
| Operating Software | 3 Types (Developer, User, and Hospital Mode) |
| Work Protocols (Assays) | Unlimited |
| Data Processing | Quantitative and Qualitative |
| Access Level Control | Yes (Master, Manager, and Operator) |
| O/S | Windows XP, 7, and 10 |
| Models | |
| Diamond E | System for ELISA |
| Diamond C | System for CLIA |
| Diamond M | System for ELISA & CLIA |